HPLC Column, RP C18 ABX, 3um, 4.6mm ID x 250mm Length, 100A. Cogent Brand. 1 EA.
Additional Info:
The 85318‑25P Cogent RP C18 ABX™ HPLC Column is engineered for maximum‑separation analytical workflows, delivering robust, reproducible performance across extreme mobile phase conditions (pH 2–12).
Built with a bulky end‑capped C18 phase bonded to high‑purity silica, this column minimizes secondary interactions and enhances chromatographic performance for acidic, basic, hydrophobic, and neutral analytes, especially those with extreme pKa values.
✅ Ideal as a USP L1 alternate for methods involving strong acids or bases
250 mm Length – Maximum Separation & Highest Purity
Highest resolving power in the 3 µm ABX analytical column range
Maximizes peak capacity for highly complex mixtures
Ideal for closely related compounds and critical separations
Provides extended retention and improved separation of difficult analytes
Preferred for final method validation and highest‑purity results
✅ Selected when shorter columns (50 mm / 100 mm) cannot achieve required resolution
4.6 mm ID – Standard Analytical Platform
Compatible with standard HPLC systems
Ideal for:
method development and optimization
QC and regulated workflows
final validation methods
Typical Flow Rate Range
~0.8–1.5 mL/min
✅ Provides robust, reproducible analytical performance
3 µm Particle – High Efficiency with Manageable Pressure
Higher efficiency than 5 µm columns
Produces:
Sharper peaks
Improved resolution
Lower backpressure than 1.8 µm UHPLC columns
✅ Ideal for:
High‑performance HPLC systems
Maximum separation without UHPLC pressure requirements
Wide pH Stability (pH 2–12) – Extreme Method Capability
Designed for acidic and basic mobile phases
Suitable for:
Strong acids
Strong bases
Maintains performance under aggressive conditions
✅ Enables separations not achievable with standard C18 phases
Why Choose RP C18 ABX™ Columns (3 µm)
Extreme pH Ruggedness
Stable across full pH range (2–12)
Ideal for harsh analytical conditions and stability‑indicating methods
Improved Peak Shape for Acids & Bases
Advanced end‑capping reduces secondary interactions
Enhances reproducibility and accuracy
Maximum Separation Capability
Designed for highest resolution analytical workflows
Ideal for complex samples and regulatory methods
✅ One of the top choices for high‑resolution, extreme pH analytical methods
Application Performance Advantages
Suitable for:
Hydrophobic compounds
Neutral analytes
Long‑chain fatty acids
Enables:
Improved separation of complex sample matrices
Enhanced resolution compared to shorter column formats
✅ Ideal for final method validation and high‑purity workflows
System & Sample Considerations
Compatible with standard HPLC systems
Can be used on UHPLC systems if available
Recommended sample preparation:
👉 Use 0.2 µm syringe filters for proper sample preparation before injection
✅ Helps:
Prevent column clogging
Maintain long‑term performance and reproducibility
Typical Applications
HPLC analytical separations
Acidic and basic compound analysis
Pharmaceutical method development and validation
Stability‑indicating methods
Complex mixture and impurity profiling
High‑purity analytical workflows
Important Usage Notes
Designed for standard analytical HPLC systems (4.6 mm ID)
Suitable for extreme pH mobile phases (pH 2–12)
Ideal for maximum‑resolution and highest‑purity workflows
Monitor system pressure relative to instrument limits